Lighting transformers are electrical devices that adjust voltage levels supplied to lighting fixtures, while safeguarding them against risks. These devices help ensure the lighting fixtures receive the appropriate power needed to make them brighter or dimmer as per the requirement. At Bruce Electric Equipment, we provide a range of new, used and refurbished dry type lighting transformers from reputable brands. Whether you are looking for a solution to power lighting systems or need a tailored transformer for a specific project, our extensive product range is designed to meet your individual needs. If you have any questions about our products, please contact us.

Showing 1–15 of 41 results

T150024S

SKU: T150024S
Manufacturer: ACME
Weight: 35 lsb

KVA : 1500

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 24-Dec

HZ : 60

TEMP RISE : 120

ENCLOSURE : ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-150024-S

T15012S

SKU: T15012S
Manufacturer: ACME
Weight: 9 lsb

KVA : 150

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 12

HZ : 60

TEMP RISE : 120

ENCLOSURE : ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-15012-S

T100012S

SKU: T100012S
Manufacturer: ACME
Weight: 28 lsb

KVA : 1

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 12

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-100012-S

T100024S

SKU: T100024S
Manufacturer: ACME
Weight: 28 lsb

KVA : 1

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-100024-S

T10024S

SKU: T10024S
Manufacturer: ACME
Weight: 9 lsb

KVA : 0.1

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-10024-S

T111683

SKU: T111683
Manufacturer: ACME
Weight: 24 lsb

KVA : 1

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-1-11683

T111684

SKU: T111684
Manufacturer: ACME
Weight: 30 lsb

KVA : 1.5

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-1-11684

T111685

SKU: T111685
Manufacturer: ACME
Weight: 38 lsb

KVA : 2

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-1-11685

T111686

SKU: T111686
Manufacturer: ACME
Weight: 55 lsb

KVA : 3

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-1-11686

T111687

SKU: T111687
Manufacturer: ACME
Weight: 75 lsb

KVA : 5

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA ENCAPSULATED

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-1-11687

T211688

SKU: T211688
Manufacturer: ACME
Weight: 125 lsb

KVA : 7.5

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA 2

TYPE : Lighting Transformers

OLD PART NUMBER : T-2-11688

OTHER : D

T211689

SKU: T211689
Manufacturer: ACME
Weight: 160 lsb

KVA : 10

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24-Dec

HZ : 60

ENCLOSURE : NEMA 2

TYPE : Lighting Transformers

OLD PART NUMBER : T-2-11689

OTHER : D

T25012S

SKU: T25012S
Manufacturer: ACME
Weight: 12 lsb

KVA : 0.25

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 12

HZ : 60

TEMP RISE : 120

ENCLOSURE : NEMA 2

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-25012-S

T25024S

SKU: T25024S
Manufacturer: ACME
Weight: 12 lsb

KVA : 0.25

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 24-Dec

HZ : 60

TEMP RISE : 120

ENCLOSURE : NEMA 2

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-25024-S

T50012S

SKU: T50012S
Manufacturer: ACME
Weight: 17 lsb

KVA : 500

PHASE : SINGLE

PRIMARY VOLTAGE : 120

SECONDARY VOLTAGE : 12

HZ : 60

TEMP RISE : 120

ENCLOSURE : NEMA 3R

TYPE : Low Voltage Lighting Transformers

OLD PART NUMBER : T-50012-S

How Lighting Transformers Work

 

Our dry-type transformer possesses a robust design that eliminates the need for liquid insulation. This makes them safer and more reliable, as they reduce the fire risk and are easier to maintain. The construction of these transformers ensures that they perform efficiently while withstanding various environmental conditions. These transformers feature primary and secondary coil, which is wrapped around a common iron core. The working of these transformers would depend on their designs. Based on designs, our dry type lighting transformers are designed to perform the following functions:

 

  • Voltage Conversion: The electric current creates a magnetic field around the core when it flows through the primary winding. This field induces a current in the secondary winding and transforms the voltage. The transformers step up or down the voltage depending on the turns in the primary and secondary winding.
  • Stepping Down Voltage: The transformers usually step down the voltage from a higher level for lighting applications. For instance, they may step down the voltage from 120V or 240V to safer levels such as 12V or 24V for halogen or LED lights.
  • Isolation: The transformers help create electric isolation between the lighting circuit and the power source. This helps improve the lighting safety and reduce the risk of electrical shocks.
  • Regulating Power Supply: These transformers help regulate the power supply to ensure a consistent voltage supply to the lighting system. Regulating power supply transformers protect the lights from fluctuations and surges that can damage them.

 

Benefits of Dry Type Lighting Transformers

 

Dry type lighting transformers have gained immense popularity due to the following reasons:
 

  • Safety and Reliability: Dry type lighting transformers use air as a coolant compared to other oil-filled transformers, lowering the fire risk. Our dry type lighting transformers are designed keeping safety in mind which makes them an ideal choice for indoor and enclosed spaces.
  • Maintenance and Longevity: With no oil to monitor or replace, these transformers offer a longer operational life and reduced operational costs than their oil-filled counterparts.
  • High Efficiency and Reliability: These transformers possess excellent insulation properties, ensuring reduced energy losses and excellent performance. Our transformers can withstand short circuits and higher levels of stress.
  • Energy Efficiency: Our lighting transformers are designed to maximize energy efficiency. Maintaining the correct voltage levels helps minimize energy waste and reduce operational costs.
  • Environmental Considerations: Dry-type transformers are environmentally friendly due to their lack of liquid insulation. This design choice eliminates the risk of hazardous spills and makes these transformers a more eco-conscious option for your lighting needs.
  • Quiet Operation: These transformers operate quietly, making them ideal for noise-sensitive environments, such as hospitals, buildings, and residential complexes.
  • Flexible Installations: Compact designs of our dry type lighting transformers contribute to their flexibility and suitability for limited spaces. These transformers can be mounted closer to the load, helping reduce associated energy losses and long cable runs.

 

Applications of Dry Type Lighting Transformers

 

Our dry type lighting transformers are used in the following applications.

 

  • Commercial Lighting: Our transformers are widely used in office buildings, retail spaces, and shopping malls for low-voltage applications. These transformers help step-down the voltage for lighting system, ensuring their safe and efficient operation.
  • Industrial Lighting: In industrial settings such as factories and warehouses, our dry-type lighting transformers provide reliable power to support robust lighting systems. They help improve the safety and visibility in work areas with minimal maintenance requirements.
  • Public Infrastructure: Efficient lighting is crucial for functionality and safety in public places, such as train stations, airports, and sports arenas. Our transformers are also used in street lighting, park lighting, and other public spaces. They provide stable lighting for crucial applications.
  • Specialty Lighting: For applications requiring specialized lighting, such as museums or theaters, our transformers provide the precise voltage control needed to support unique lighting setups.
  • Residential Complexes: Our lighting transformers are used in apartment complexes for safe voltage conversion for lighting fixtures. They help improve the safety of lighting systems in open spaces.

 

Tips to Choose the Right Lighting Transformer

 

There are several factors to consider when choosing dry type lighting transformers for your applications. These transformers help ensure optimal safety, efficiency, and performance of lighting fixtures. Here are some key considerations to make primarily:

 

  • Determine the voltage requirements: The common input voltages for lighting fixtures is 120V, 240V, or 480V and output voltages for low-voltage lighting fixtures is 12V or 24V. Analyze the voltage requirements of your system. Check if the transformer can provide stable voltage output under varying load conditions to prevent damages to lights or flickering.
  • Determine the power requirements: Analyze the total power requirements of your system by calculating the combined wattage of connected lights. It is always better to choose a transformer that has a higher power rating than required, as it can handle any future expansions. The transformer must be efficient enough to handle the current draw of the lighting system without overheating.
  • Address the requirements of application environment: Where do you plan to use the transformer – indoors or outdoors? Your selection will depend on this consideration. For instance, if you plan to use these transformers in damp outdoor locations, choose a transformer with the appropriate IP rating. Depending on the operating environment, you must also consider other factors, such as cooling features in poorly ventilated spaces.
  • Evaluate safety and compliance standards: Choose transformers that meet industry standards and certifications, such as CSA, UL, and IEC to ensure compliance with local regulations.
  • Assess energy savings: Focus on a transformer design that helps minimize energy losses. Choosing models with high operational efficiency and low no-load losses is always better.

 

Ready to enhance your lighting systems with Bruce Electric’s low voltage dry type lighting transformers? <>Contact us today for more information or to request a quote. Explore our product range and discover the perfect solution for your lighting needs.

 

Frequently Asked Questions on Lighting Transformers

 

  • What is the lifespan of a low-voltage lighting transformer?

     

Low-voltage lighting transformers typically last between 10 to 15 years, depending on usage and environmental conditions.
 

  • Are your dry type lighting transformers suited for environments with corrosive elements or high humidity?

 

Many models available with us are suitable for environments with corrosive elements and high humidity. We recommend you to choose the models with proper enclosure rating, such as IP-rated or NEMA. These ratings protect against dust, humidity, and corrosive elements. You can also find models with enclosures made of stainless steel or special coatings for such conditions.

 

  • How to check if the chosen model of dry type lighting transformer is compatible with LED lighting systems?

     

The transformer must have a stable output voltage with low inrush current and minimal harmonic distortion. Check if the transformer is rated for the power and voltage requirements of your LED fixtures.

 

  • How do I choose a dry type lighting transformer for applications with high voltage fluctuations?

     

Choose a transformer with good voltage regulation characteristics for environments with frequent voltage fluctuations. Transformers with stabilization features and built-in surge protection will help ensure consistent performance and protect lighting systems from potential damage due to voltage spikes or drops.